smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.10.0-33-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.12
Device Model:     ST3320418AS
Serial Number:    9VM2639M
LU WWN Device Id: 5 000c50 0156e96fd
Firmware Version: HP11
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Mon Sep 18 14:30:32 2017 IST

==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/213891en

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  625) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  74) minutes.
SCT capabilities: 	       (0x103f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   105   099   006    Pre-fail  Always       -       9405733
  3 Spin_Up_Time            0x0023   098   097   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   096   096   020    Old_age   Always       -       4356
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002f   061   054   030    Pre-fail  Always       -       1271704818194
  9 Power_On_Hours          0x0032   085   085   000    Old_age   Always       -       13695
 10 Spin_Retry_Count        0x0033   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   096   096   020    Old_age   Always       -       4358
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   094   094   000    Old_age   Always       -       6
188 Command_Timeout         0x0032   100   098   000    Old_age   Always       -       190
189 High_Fly_Writes         0x003a   099   099   000    Old_age   Always       -       1
190 Airflow_Temperature_Cel 0x0022   070   056   045    Old_age   Always       -       30 (Min/Max 30/31)
194 Temperature_Celsius     0x0022   030   044   000    Old_age   Always       -       30 (0 21 0 0 0)
195 Hardware_ECC_Recovered  0x003a   047   042   000    Old_age   Always       -       9405733
196 Reallocated_Event_Count 0x0032   100   100   036    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       2
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 6 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 6 occurred at disk power-on lifetime: 12941 hours (539 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 ff ff ff ef 00      03:40:51.264  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:40:51.262  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:40:51.262  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:40:51.262  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:40:51.261  READ DMA EXT

Error 5 occurred at disk power-on lifetime: 12941 hours (539 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 ff ff ff ef 00      03:40:48.367  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:40:48.365  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:40:48.363  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:40:48.362  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:40:48.361  READ DMA EXT

Error 4 occurred at disk power-on lifetime: 12941 hours (539 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 ff ff ff ef 00      03:36:27.301  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:36:27.301  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:36:27.301  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:36:27.301  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:36:27.300  READ DMA EXT

Error 3 occurred at disk power-on lifetime: 12941 hours (539 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 00 ff ff ff ef 00      03:36:24.113  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:36:24.054  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:36:24.054  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:36:24.052  READ DMA EXT
  25 00 00 ff ff ff ef 00      03:36:24.051  READ DMA EXT

Error 2 occurred at disk power-on lifetime: 12941 hours (539 days + 5 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  25 00 08 ff ff ff ef 00      03:06:21.100  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:06:21.099  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:06:21.099  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:06:21.098  READ DMA EXT
  25 00 08 ff ff ff ef 00      03:06:21.098  READ DMA EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     13695         -
# 2  Extended offline    Interrupted (host reset)      70%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.